Description

Monitors the system CPU utilization, system memory utilization, system uptime, power supply, power alarm status, fan operational status and the current temperature of the ExtremeXOS switch. Validated on ExtremeXOS X440 switch
(SysObjID: enterprises.1916.2.175, enterprises.1916.2.177).

Prerequisites

SNMP should be enabled in end device and device should support EXTREME-SOFTWARE-MONITOR-MIB, EXTREME-SYSTEM-MIB OIDs and SNMP credentials should be attached against the device in portal.

How to Apply: This template is All instance selection based. It will not ask user to select any instance(s) while assigning it to a device.

Metric Parameters

Metric Parameters
ParameterDescription
Frequency
  • Frequency is the interval in which you want to probe and collect metric data from the target device/resource
  • Frequency is defined in minutes (min).
  • Warning ThresholdIf the metric value satisfies the condition defined along with Warning Threshold value, then a notification is sent to the user.
    Critical ThresholdIf the metric value satisfies the condition defined along with Critical Threshold value, then a notification is sent to the user.
    AlertThe alert value can be set to either Yes or No. If it is Yes, then an alert message is sent to the user.

    Metrics

    system.uptime

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.2.1.1.3.0
    ExpressionsysUpTime/100
    DescriptionThe time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameSystem Uptime
    Units

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorLESS_THAN_EQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold1800
    0 - 4294967295
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Uptime

    Uptime

    extreme.fan.operational.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.1916.1.1.1.9.1.2
    ExpressionNULL
    DescriptionThis monitor provides the operational status of a cooling fan. The possible status values are : 1- True and 2- False , which are boolean. [OID: 1.3.6.1.4.1.1916.1.1.1.9.1.2]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameExtreme XOS Fan Operational Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold2[{"1":"True"},{"2":"False"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Extreme Fan Operational Status

    Extreme Fan Operational Status

    extreme.current.temperature

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.1916.1.1.1.8.0
    ExpressionNULL
    DescriptionThis monitor provides the current temperature in degrees Celsius measured inside device enclosure. [OID: 1.3.6.1.4.1.1916.1.1.1.8.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameExtreme XOS Current Temperature and Power Alarm Status
    UnitCelsius

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning OperatorGREATER_THANEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold550°C - 100°C
    Warning Repeat Count11-12
    Critical OperatorGREATER_THANEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold600°C - 100°C
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Extreme Current Temperature

    Extreme Current Temperature

    extreme.power.alarm.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.1916.1.1.1.22.0
    ExpressionNULL
    DescriptionThis monitor provides the alarm state of the power supply to a device. Alarm state indicates either fan failure or overtemperature condition. The possible status values are 1- True and 2- false.
    [OID: 1.3.6.1.4.1.1916.1.1.1.22.0]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameExtreme XOS Current Temperature and Power Alarm Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    Filter
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold1[{"1":"True"},{"2":"False"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Extreme Power Alarm Status

    Extreme Power Alarm Status

    extreme.system.memory.utilization

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.1916.1.32.2.2.1.2,
    1.3.6.1.4.1.1916.1.32.2.2.1.4
    Expression(extremeMemoryMonitorSystemUsage / extremeMemoryMonitorSystemTotal) * 100
    DescriptionMonitors the total amount of memory used by system services in %.
    [OIDs: 1.3.6.1.4.1.1916.1.32.2.2.1.2, 1.3.6.1.4.1.1916.1.32.2.2.1.4]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameExtreme XOS System Memory Utilization
    Unit%

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorGREATER_THANEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold700-100
    Warning Repeat Count21-12
    Critical OperatorGREATER_THANEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold800-100
    Critical Repeat Count21-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    System Memory Utilization

    System Memory Utilization

    extreme.system.memory.free

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.1916.1.32.2.2.1.3
    ExpressionNULL
    DescriptionTotal amount of free memory in Kbytes in the system. [OIDs: 1.3.6.1.4.1.1916.1.32.2.2.1.3]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameExtreme XOS System Memory Utilization
    UnitKB

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical Operator
    Critical Threshold
    Critical Repeat Count
    AlertNoYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    System Memory Free

    System Memory Free

    extreme.power.supply.status

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.1916.1.1.1.27.1.2
    ExpressionNULL
    DescriptionThis monitor provides the status of the power supply. Possible status values are 1 - Not Present , 2- Present and OK , 3- Present and NOT OK. [OID: 1.3.6.1.4.1.1916.1.1.1.27.1.2]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameExtreme XOS Power Supply Status
    Unit

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning Operator
    Warning Threshold
    Warning Repeat Count
    Critical OperatorEQUALEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold3[{"1":"notPresent"},{"2":"presentOK"},{"3":"presentNotOK"}]
    Critical Repeat Count11-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    Extreme Power Supply Status

    Extreme Power Supply Status

    extreme.system.cpu.utilization.5min

    Metric Details

    Metric Details
    Applicable forDevice
    SNMP OID1.3.6.1.4.1.1916.1.32.1.4.1.9
    ExpressionNULL
    DescriptionMonitors the CPU utilization by system resources. This is the CPU utilization of the system resources in the last 5 minutes. [OIDs: extremeCpuMonitorSystemUtilization5mins - 1.3.6.1.4.1.1916.1.32.1.4.1.9]
    CategorySNMP monitors
    Collector TypeGateway
    Monitor NameExtreme XOS System CPU Utilization
    Unit%

    Possible Inputs

    Possible Inputs
    MetricInput ValueRange of Values
    Frequency51 – 1440 (mins)
    FilterNULLNot Applicable
    Warning OperatorGREATER_THANEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Warning Threshold700-100
    Warning Repeat Count21-12
    Critical OperatorGREATER_THANEnds with, ==, !=, >=, <=, >, <, In Range, Out of range, Equals, Not equals, Equals Ignore Case, Not Equals Ignore Case, Contains, Not contains, Regex match, Regex no match, In string list, Not in string list, In List, Not in list, Starts with
    Critical Threshold800-100
    Critical Repeat Count21-12
    AlertYesYes/No
    Graph (Yes/No)YesYes/No

    Sample Output

    CPU Utilization 5min

    CPU Utilization 5min